Edition
Manual
2014-09-09 Workshop Manual, GGP Park 6 Control wires
Stopping time check
1. Run the machine at full speed with the
cutting deck activated.
2. Rise from the seat and start the time
measurement.
3. The time from rising from the seat to that
the cutting deck has complete stopped is
not allowed to exceed 5/7 seconds as
follows:
For cutting decks with a cutting width of
under 120 cm - 5 seconds.
For cutting decks with a cutting width of 120
cm or more - 7 seconds.
4. If the time above is exceed, the
adjustments must be repeated.
Warning!
If the stopping time exceed 5/7 sec-
onds, the machine is not allowed to
be used.
Chapter
Page
21