Benchmark And Info Menu - Worcester Greenstar 4000 Installation And Maintenance Instructions Manual

Gas-fired condensing combi appliance
Hide thumbs Also See for Greenstar 4000:
Table of Contents

Advertisement

Settings in the service menu
7.2.2

Benchmark and Info menu

Menu item
Flow temp.
DHW flow rate
Hot water temp.
Table 22 Benchmark menu
Menu item
Current status
Current fault
Fault history
Boiler
Max. heat output
Actual temp.
Set flow temp.
HEx temperature
Act. burner mod.
Burner output
Ionisation current
Pump mod.
Outside temp.
Burner starts
Hours run
System pressure
Hot water
Max. output
DHW flow rate
DHW act. temp.
Hot water temp.
1)
Inlet temp.
DHW set temp.
2)
Autom. filling
System pressure
Last refill dur.
Status
Refilling active
System
Contr.device ver.
Progr. unit ver.
SW sub-ver.
Code plug no.
Code plug ver.
3)
Key
4)
Solar
Collector temp.
Cyl.temp.bottom
Collector pump
Solar fault
1) Only available if DHW preheat kit is fitted
2) Menu items only visible if automatic filling facility fitted
3) Only available with installed Key Timer (accessory)
4) Menu items only visible if Solar connected
Table 23 Info menu
52
Remark/restriction
Flow temperature in °C
Hot water flow rate in l/min
Outlet temperature in °C
Remark/restriction
 10.1.2 "Operating/Fault code table", page 71 for operating codes.
 10.1.2 "Operating/Fault code table", page 71 for fault codes.
Last 10 faults in chronological order
Maximum heating output in kW
Current flow temperature in °C
Target flow temperature in °C
Primary heat exchanger temperature
Current burner modulation %
Current burner output in kW
Current ionisation current in μA
Current pump modulation %
Current outside temperature in °C
Number of burner starts since commissioning
Run time of the system since commissioning
Current system pressure in bar
Maximum domestic hot water output in kW
Current DHW flow rate in l/min
Current domestic hot water temperature in °C
Current domestic hot water temperature in °C
Cold mains inlet temperature in °C (when DHW Pre-heat Kit accessory is fitted)
DHW target temperature
Current system pressure in bar
Duration of last refill
Not ready / Ready
Automatic filling On/Off
Software version of the control device
Software version of the control unit
Software sub-version
Code plug number
Code plug version
Type of control Key installed e.g. "Comfort+RF Key
Collector temperature in °C
Cylinder temperature, bottom sensor in °C
Collector pump
Current faults
Greenstar 4000 – 6 720 891 161 (2020/09)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gr4700iw c

Table of Contents