10.1.3 Faults That Are Not Displayed - Worcester Greenstar 4000 Installation And Maintenance Instructions Manual

Gas-fired condensing combi appliance
Hide thumbs Also See for Greenstar 4000:
Table of Contents

Advertisement

10.1.3 Faults that are not displayed

Appliance faults
Combustion noises too loud; rumbling noises
Flow noises
Heat-up takes too long.
Flue gas values incorrect; CO content too high.
Delayed ignition, poor ignition.
Condensate in air box
Combi boilers: hot water outlet temperature is not
reached.
Combi boilers: DHW volume is not reached.
No function, the display remains dark.
Table 32 Faults that are not shown on the display
Greenstar 4000 – 6 720 891 161 (2020/09)
Remedy
▶ Check the gas type.
▶ Check the gas supply pressure.
▶ Check the flue system; clean or repair if required.
▶ Check the gas/air ratio.
▶ Check the gas valve; replace if required.
▶ Set the pump rate or pump characteristic map correctly and match to the maximum
output.
▶ Set the pump rate or pump characteristic map correctly and match to the maximum
output.
▶ Check the gas type.
▶ Check the gas supply pressure.
▶ Check the flue system; clean, repair or replace if required.
▶ Check the gas/air ratio.
▶ Check the gas valve; replace if required.
▶ Check the ignition transformer function for misfiring in the Function check menu
Ignition test, replace if required.
▶ Check the gas type.
▶ Check the gas supply pressure.
▶ Check the power supply.
▶ Check the electrodes with cable; replace if required.
▶ Check the flue system; clean or repair if required.
▶ Check the gas/air ratio.
▶ For natural gas: check the external gas flow monitor, replace if required.
▶ Check the burner, replace if required.
▶ Check the gas valve; replace if required.
▶ Check the non-return valve in the burner hood assembly, replace if required.
▶ Check the turbine, replace if required.
▶ Check the gas/air ratio.
▶ Check for reversed pipework or cross leaking mixing units such as showers.
▶ Check the plate heat exchanger.
▶ Check the electrical wiring for damage.
▶ Replace defective cables.
▶ Check the fuse, replace if required. One spare fuse is supplied.
Fault finding and diagnosis
79

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gr4700iw c