Lubrication; Grease Specification; Greasing The Caster Pivots - Toro Spray Master Operator's Manual

36in sprayer
Hide thumbs Also See for Spray Master:
Table of Contents

Advertisement

Closing the Tanks
1.
Rotate the tank closed as shown in
Figure 63
2.
Align the hole in the tank lock plate with the hole
in the support
(Figure
Figure 64
Left shown, the right tank is similar.
1. Flange-head bolt
2. Tank lock plate
3.
Assemble the flange-head bolt through the holes
in the lock plate and support, and secure the bolt
with the flange locknut
4.
Torque nut and bolt to 91 to 113 N∙m (67 to 83
ft-lb).
Figure
63.
g311944
64).
g311931
3. Support
4. Flange locknut
(Figure
64).

Lubrication

Grease Specification

Grease type: National Lubricating Grease Institute
(NGLI) grade No. 2 multi-purpose gun grease.

Greasing the Caster Pivots

Service Interval: Every 80 hours/Every 2 weeks
(whichever comes first)
1.
Prepare the machine for maintenance; refer to
Preparing the Machine (page
2.
Wipe the grease fittings at caster clean with a
rag
(Figure
65).
3.
Connect a grease gun to the fittings
4.
Pump grease into the fittings until grease begins
to come out of the bearings.
5.
Wipe up any excess grease.
6.
Repeat steps
pivot.
51
49).
Figure 65
(Figure
1
through
5
at the other caster
g312856
65).