Power Specifications - Avaya 5900 Series Installing Manual

Ethernet routing switch
Hide thumbs Also See for 5900 Series:
Table of Contents

Advertisement

Installation preparation
Operating Humidity
Storage Humidity
Maximum Operating Altitude
Storage Altitude
Acoustic Noise
Miscellaneous Operating
Considerations

Power specifications

This section provides the following specifications for Ethernet Routing Switch 5900 Series.
The following table describes the AC power specifications.
September 2017
5928GTS/5928GTS-PWR+/5928GTS-uPWR/5952GTS/5952GTS-
PWR+/59100GTS/59100GTS-PWR+:
• 0 to 95 percent non-condensing
5928MTS-uPWR:
• 0 to 85 percent non-condensing
5928GTS/5928GTS-PWR+/5928GTS-uPWR/5952GTS/5952GTS-
PWR+/59100GTS/59100GTS-PWR+:
• 10 to 95 percent non-condensing
5928MTS-uPWR:
• 10 to 85 percent non-condensing
3048 m (10,000 feet)
-304.8 to 12,192 m (-1,000 to 40,000 feet) above sea level
At 25°C Ambient Temperature, less than 52 dBA typical, at 50°C, less
than 60 dBA.
The system should never exceed 70dBA.
• No heat sources such as hot air vents or direct sunlight located near
the switch
• No sources of severe electromagnetic interference located near the
switch.
• No excessive dust in the environment.
• An adequate power source is located within 6 feet (1.83 meters) of
the switch. One 15-amp circuit is required for each power supply.
• At least 2 inches (5 centimeters) on all sides of the switch unit for
ventilation
• Cables should be dressed to prevent blocking air flow.
• Adequate clearance is allotted at the front and rear of the switch for
access to cables.
Installing Avaya ERS 5900 Series