Procedure 6.1 - Troubleshooting The Lower And Upper Interconnect Cables - Precor C576i Service Manual

Self powered elliptical fitness crosstrainer
Table of Contents

Advertisement

Procedure 6.1 - Troubleshooting the Lower and Upper
Anti-static kits can be ordered from Precor (part number 20024-101).
Troubleshooting the Upper Interconnect Cable
1.
Remove the five screws from the rear of the upper display housing. Remove the display
housing front panel from the display housing. Disconnect the upper interconnect cable from
the upper PCA.
2.
Remove the four screws from the access cover below the display. Disconnect the upper
interconnect cable from the mid-point connector. Refer to Diagram 6.1
Diagram 6.1 - Data Cable Mid-Point Connector
3.
External of the upper column, connect a replacement upper interconnect cable to the
mid-point connector and the upper PCA.
4.
Check operation as described in Section 4. If the unit works properly, replace the upper
interconnect cable as described in Procedure 7.4.
5.
If the symptoms are unchanged, remove the external upper interconnect cable. Reconnect
the internal upper interconnect cable to the mid-point connector and the upper PCA. Set the
display housing front panel in it's mounting position and fasten it with the five mounting
screws removed in step 1. Trouble shoot the lower interconnect cable starting with step 6.
Interconnect Cables
C576i Self Powered Elliptical Fitness Crosstrainer
Upper
Interconnect
Cable
Mid-Point
Connector
Lower
Interconnect
Cable
Page 21