Troubleshooting the Lower Interconnect Cable
6.
Remove the right side rear cover as described in procedure 7.1.
7.
Disconnect the lower interconnect cable from the mid-point connector and the lower PCA.
Refer to Diagram 5.1.
8.
External of the frame, connect a replacement lower interconnect cable to the mid-point
connector and the lower PCA.
9.
Check operation as described in Section 4. If the unit works properly, replace the lower
interconnect cable as described in Procedure 7.4.
10. If the symptoms are unchanged, remove the external lower interconnect cable. Reconnect
the internal lower interconnect cable to the mid-point connector and the lower PCA. Remove
the upper and lower interconnect cables from the mid-point connector. Connect a
replacement mid-point connector between the two interconnect cables and retest the unit
per Procedure 4.
11. If you have performed all of the procedures above and have been unable to correct the
problem, call Precor customer support.