Procedure 6.1 - Troubleshooting The Lower And Upper Interconnect Cable - Precor EFX 5.33 Service Manual

Elliptical fitness crosstrainer
Hide thumbs Also See for EFX 5.33:
Table of Contents

Advertisement

Procedure 6.1 - Troubleshooting the Lower and Upper
Typical symptoms associated with a defective interconnect cable is either an error 30 or no
power to the upper PCA. This procedure requires that you have a known good upper
interconnect cable, lower interconnect cable and mid-point connector.
1.
Set the on/off switch in the off position.
2.
If you are troubleshooting an error 30, 31 or 32 continue with step 3, otherwise see
Procedure 6.5.
3.
Pry the end cap out of the front of the frame base tube (See Diagram 6.1).
4.
Carefully withdraw both cables and mid-point connector.
Diagram 6.1 - Interconnect Cables and Mid-Point Connector
Lower
Interconnect
Cable
End Cap
Mid-point
Connector
5.
Disconnect both cables from the mid-point connector and replace the mid-point connector
with a known good mid-point connector. If the mid-point connector does not correct the
problem, replace the original mid-point connector and continue with step 5.
Interconnect Cable
5.33 Elliptical Fitness Crosstrainer
Upper
Interconnect
Cable
Page 23

Advertisement

Table of Contents
loading

Table of Contents