Procedure 6.1 - Troubleshooting the Lower and Upper
Anti-static kits can be ordered from Precor (part number 20024-101).
Troubleshooting the Upper Interconnect Cable
1.
Set the on/off switch in the "off" position.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
2.
Attach the anti-static wrist strap to your arm, then connect the ground lead of the wrist strap
to the units frame.
3.
Remove two screws that fasten the upper mid-point cover. Remove two screws that fasten
the lower mid-point cover. Remove both halves of the cover and the split gasket. See
Diagram 6.1
Diagram 6.1 - Mid-Point Cover
Upper Cover
Lower Cover
4.
Remove the four screws from the rear of the upper display housing. Remove the display
housing front panel from the display housing. Disconnect the upper interconnect cable from
the upper PCA (connector J5).
Interconnect Cables
C556 Elliptical Fitness Crosstrainer
Split Ring
Upper Cover
Mounting Screw
Lower Cover
Mounting Screw