Safe Mode - Omron V680S Series User Manual

Hide thumbs Also See for V680S Series:
Table of Contents

Advertisement

Section 7
Troubleshooting

Safe Mode

In addition to the Run Mode that is used for normal operation, the Reader/Writer supports a Safe Mode
operation mode. The Safe Mode is used when you do not remember the IP address that is set in the Reader/
Writer.
If the Reader/Writer starts in Safe Mode, the following settings are always used. This allows you to access the
Reader/Writer even if you forget the IP address so that you can set the IP address again.
IP address
Subnet mask
Port number
When the Reader/Writer is running in safe mode, some functions can not be used (Ex. RF tag communication and noise
measurement function, etc). When you use the Reader/Writer normally, please start the Reader/Writer in RUN mode.
Starting in Safe Mode
(1) Connect the control signal line (violet) from the Cable to the GND terminal on the DC power supply.
Connect the other two lines (24P (brown) and 24N (blue)) to the DC power supply terminals.
(2) Turn ON the power supply to the Reader/Writer.
(3) The RUN indicator on the Reader/Writer will flash green
After the Reader/Writer starts in Safe Mode, use the Web browser or a Modbus query from the host
device to reset or initialize the IP address.
If an error occurs in the Reader/Writer, the Reader/Writer may automatically start in Safe Mode
Refer to Error Descriptions in this Section for for more information.
RFID System
170
User's Manual
192.168.1.200
255.255.255.0
502
p.158

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680s-hmd64-etnV680s-hmd66-etn

Table of Contents