Installation and Connections
 V680-D1KP66MT
Mount the RF Tag using M3 flat-head screws
from the marked side.
Tighten the screws to a torque of 0.3 to 0.5 N·m.
When you install the RF tag, please have the bracket as shown in the figure below.
Material: Steel, SUS
Although it is possible to use aluminum in addition to iron and copper as a mounting bracket, communication
performance will change depending on the material. Please do not use resin as a mounting bracket.
Refer to Influence of Surrounding Metal in Section 8 Appendices for information on the effect of metal at the back
surface of the V680-D1KP66MT.
RFID System
64
User's Manual
Two, M3 hole
25
±0.2
34
(Unit: mm)
p.215
Mounting Hole Dimensions