Section 5
Host Communications Specifications
 Execution Example
Reading the Communications Error Log When a Communications Error Occurred at the Remote Node
with IP Address 192.168.1.2 at an Operating Time of 1111111111 and a Communications Error
Occurred at the Remote Node with IP Address 192.168.1.3 at an Operating Time of 2222222222
TX: 000000000006FF03C6000061
RX: 00000000000A5FF03A20002423A35C7C0A80102ccccccccrrrrrrrr84746B8EC0A80103ccccccccrrrrrrrr00000000···00
(cccccccc: communications query information, rrrrrrrr: communications response information)