4.
Verify that a link exists by checking that the port Link/Activity LED is on (blinking 
green or solid green). If the Link/Activity LED is off, perform the following steps until 
it is on:
a.
Verify that the device at the other end of the segment is ON and connected to the 
segment.
b. If there are separate fiber‐optic connections on the other device, check the 
crossover of the cables. Swap the cable connections if necessary.
c.
Check that the fiber‐optic connection meets the dB loss and cable specifications 
outlined in the Cabling Guide for multimode cabling. To obtain this document, 
refer to "Related Documents"  on page xvi. 
If a link has not been established, refer to Chapter
a problem persists, refer to "Getting Help" on page 1‐7 for details on contacting 
Enterasys Networks for support.
5.
Repeat steps 1 through 4, above, until all connections have been made.

Connecting Fiber-Optic Cables to LC Ports

Warning: Do not use optical instruments to view laser output. The use of optical
instruments to view laser output increases eye hazard.
Advertencia: No utilizar instrumentos opticos para ver el laser. El uso de instrumentos
opticos para ver el laser incrementa el riesgo de perdida de la vision.
Warnhinweis: Benutzen sie keinesfalls optische Hilfmittel, um die Funktion des Lasers zu
überprüfen, es könnte ihr Augenlicht gefährden.
This section describes how to connect 
a 1000BASE‐SX multimode fiber‐optic segment from the network or other devices to 
an LC port connector of a Mini‐GBIC (MGBIC‐LC01 or MGBIC‐LC03), or 
a 1000BASE‐LX single‐mode fiber‐optic segment from the network or other devices to 
an LC port connector of a Mini‐GBIC (MGBIC‐LC09).
Each fiber‐optic link consists of two fiber‐optic strands within the cable:
Transmit (TX)
Receive (RX)
The transmit strand from a device port connects to the receive port of a fiber‐optic Gigabit 
Ethernet device at the other end of the segment. The receive strand of the applicable LC 
port connects to the transmit port of the fiber‐optic Gigabit Ethernet device.
Enterasys recommends labeling fiber‐optic cables to indicate receive and transmit ends. 
Many cables are pre‐labeled, providing matching labels or tapes at both ends of each 
strand of cable.
Connecting to the Network
4 for LED troubleshooting details. If 
SecureStack C2 Installation Guide 3-27