Replace the Hydraulic Filters
Genie specifications require that this procedure be
performed every 2000 hours.
Replacement of the hydraulic tank return filter is
essential for good machine performance and
service life. A dirty or clogged filter may cause the
machine to perform poorly and continued use may
cause component damage. Extremely dirty
conditions may require that the filter be replaced
more often.
Tank breather filter (if equipped):
1
Remove and discard the hydraulic tank
breather cap.
2
Install a new cap onto the tank.
Replace the Hydraulic Return Filter
GS-1530/1532, GS-1930/1932, GS-
2032/2632, GS-55, GS-69, GS-84, GS-90
Models with hydraulic drive
1
Clean the area around the return filter.
2
Remove the return filter.
3
Apply a thin layer of fresh oil to the gasket of
the new oil filter.
4
Install the new filter and tighten it securely by
hand.
5
Use a permanent ink marker to write the date
and number of hours from the hour meter on
the oil filter.
6
Raise the platform to approximately 3 ft / 1 m.
7
Inspect the filter for leaks.
8
Clean up and properly dispose of any oil that
may have spilled during the installation
procedure.