Viessmann Vitotwin 300-W Installation And Service Instructions For Contractors page 96

Micro chp boiler based on stirling engine natural gas version
Hide thumbs Also See for Vitotwin 300-W:
Table of Contents

Advertisement

Codes
Changing codes
Function
"Heating circuit 1 with
prim contr/system
pump"
Connecting line to the
heating circuit with/without
upstream control equip-
ment or feed pump.
"Optg mode change-
over"
"Heating circuit 2"
Function
"Room temperature
comfort setpoint"
"Room temperature re-
duced setpoint"
"Room temperature frost
protection setpoint"
"Heating curve slope"
(see page 81)
"Heating curve displace-
ment" (see page 81)
"Summer/winter heating
limit" (see page 159)
"24-hour heating limit"
(see page 159)
"Flow temp setpoint
min"
"Flow temp setpoint
max"
"Room temperature in-
fluencing factor"
96
(cont.)
Code
Operat-
ing level
872
"F2"
900
"F2"
Code
Operat-
ing level
1010
"E"
1012
"E"
1014
"E"
1020
"F1"
1021
"F1"
1030
"F1"
1032
"F2"
1040
"F2"
1041
"F2"
1050
"F2"
Setting options
■ "No"
■ "Yes"
■ "None"
■ "Frost protec-
tion mode"
■ "Reduced"
■ "Comfort"
■ "Automatic"
Setting options
6 to 35 °C
6 to 35 °C
4 to 35 °C
0.10 to 4.00
- 4.5 to 4.5 °C
- - -/8 to 30 °C
- - -/- 10 to 10 °C
8 to 95 °C
8 to 95 °C
- - -/0 to 100 %
Delivered
condition
"Yes"
"None"
Delivered
condition
20.0
14.0
4.0
1.40
0.0
18
0
20
80
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C3ha

Table of Contents