Changing codes
"Burner sequence"
Function
"Locking time min supp
bu" (see page 156)
"Advanced enable supp
bu DHW" (see page 156)
"Rel time min mod supp
bu" (see page 156)
"Rel integr mod supp
bu" (see page 156)
"Release DHW charg-
ing" (see page 156)
"Supplementary source" (see
page 155)
Function
"Setpoint incr main
source"
"Output limit main
source"
"With DHW charging"
"Release below outside
temp"
"Release above outside
temp"
(cont.)
Code
Operat-
ing level
3201
"F2"
3203
"F2"
3208
"F2"
3209
"F2"
3213
"F2"
Code
Operat-
ing level
3690
"F2"
3691
"F2"
3692
"F2"
3700
"F2"
3701
"F2"
Setting options
Delivered
condition
0 to 40 min
15
0 to 100 %
100
0 to 255 min
15
0 to 500 °C · min
100
■ "No restric-
"No restric-
tions"
tions"
■ "Stirling burn-
er only"
■ "First charg-
ing eng bu on-
ly"
■ "Fir'cha. eng
bu, supp bu
else"
Setting options
Delivered
condition
0 to 10 °C
10
1 to 100 %
80
■ "Locked"
"Substitute"
■ "Substitute"
■ "Comple-
ment"
■ "Instantly"
-50 to 50 °C
- - -
-50 to 50 °C
- - -