Viessmann Vitotwin 300-W Installation And Service Instructions For Contractors page 15

Micro chp boiler based on stirling engine natural gas version
Hide thumbs Also See for Vitotwin 300-W:
Table of Contents

Advertisement

Preparing for installation
Equipment required
Pos.
Designation
1
Vitotwin 300 W
with
2
Weather-compensated control unit
2B
Junction box for sensors and accessories (low voltage)
3A
Remote control unit FBE
3B
Wireless base station FB
4
Outside temperature sensor ATS
5
Cylinder temperature sensor STS B3
6
Buffer temperature sensor PTSO B4, top
7
Sensor for power demand function B41
8
Buffer temperature sensor PTSU B42, bottom
9
Sub-mounting kit with 3/2-way valve
DHW heating
wP
Vitocell mono mode DHW cylinder
wQ
DHW circulation pump CP (electrical connection on site)
Heating water buffer
eP
Heating water buffer cylinder Vitocell 100-E
rP
Heating circuit 1 with mixer
rQ
Extension kit for one heating circuit with mixer with integral mixer motor
and
rW
Flow temperature sensor heating circuit M1
rE
Heating circuit pump, heating circuit M1
rR
3-way mixer
or
Divicon (with 3-way mixer and heating circuit pump)
tP
Heating circuit 2 with mixer
tQ
Extension kit for one heating circuit with mixer with integral mixer motor
and
tW
Flow temperature sensor, heating circuit M2
tE
Heating circuit pump, heating circuit M2
tR
3-way mixer
or
Divicon (with 3-way mixer and heating circuit pump)
zP
Heating circuit 3 with mixer (and plate heat exchanger for system sep-
aration)
zQ
Extension kit for one heating circuit with mixer with integral mixer motor
and
zW
Flow temperature sensor, heating circuit M3
zE
Heating circuit pump, heating circuit M3
(cont.)
Preparing for installation
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C3ha