Preparing for installation
Preparing for installation
Equipment required
Pos.
Designation
1
Vitotwin 300 W
with
2
Weather-compensated control unit
2A
230 V∼ extension
2B
Junction box for sensors and accessories (low voltage)
3A
Remote control unit FBE
3B
Wireless base station FB
4
Outside temperature sensor ATS
5
Cylinder temperature sensor STS B3
6
Buffer temperature sensor PTSO B4, top
7
Buffer temperature sensor PTSU B41, bottom
8
Flow temperature sensor, common flow (common flow sensor B10)
9
Sub-mounting kit with 3/2-way valve
Heat source 2
qP
Floorstanding oil/gas boiler
qQ
Vitotronic 200, type KO1B and KO2B
qW
Outside temperature sensor ATS
qE
Cylinder temperature sensor STS
qR
Boiler water temperature sensor KTS
qT
Cylinder primary pump UPSB
qZ
3-way diverter valve
qU
External extension EA1
qI
Contactor relay
DHW heating
wP
Vitocell dual mode DHW cylinder
wQ
DHW circulation pump CP (electrical connection on site)
Heating water buffer
eP
Heating water buffer cylinder Vitocell 100-E
rP
Heating circuit 1 with mixer
rQ
Extension kit for one heating circuit with mixer with integral mixer motor
and
rW
Flow temperature sensor heating circuit M1
rE
Heating circuit pump, heating circuit M1
rR
3-way mixer
or
Divicon (with 3-way mixer and heating circuit pump)
tP
Heating circuit 2 with mixer
tQ
Extension kit for one heating circuit with mixer with integral mixer motor
and
20