Viessmann Vitotwin 300-W Installation And Service Instructions For Contractors page 27

Micro chp boiler based on stirling engine natural gas version
Hide thumbs Also See for Vitotwin 300-W:
Table of Contents

Advertisement

Preparing for installation
Pos.
Designation
2A
230 V∼ extension
2B
Junction box for sensors and accessories (low voltage)
3A
Remote control unit FBE
3B
Wireless base station FB
4
Outside temperature sensor ATS
5
Cylinder temperature sensor STS B3
6
Buffer temperature sensor PTSO B4, top
7
Buffer temperature sensor PTSU B42, bottom
8
Sensor for power demand function B41
9
Sub-mounting kit with 3/2-way valve
Solid fuel boiler
qP
Vitoligno 100-S
qQ
Boiler control unit
qW
Boiler water temperature sensor KTS
qE
Flue gas temperature sensor AGS
qR
Return temperature raising facility
qT
Boiler circuit pump KKP
qZ
Thermostatic control valve
qU
Safety equipment block
qI
Diaphragm expansion vessel
DHW heating
wP
Vitocell mono mode DHW cylinder
wQ
DHW circulation pump CP (electrical connection on site)
Heating water buffer
eP
Heating water buffer cylinders
eQ
Vitosolic for buffer changeover
eW
3-way diverter valve (R1 on Vitosolic)
eE
Temperature sensor (S1 on Vitosolic, collector temperature sensor)
eR
Temperature sensor (S2 on Vitosolic, collector temperature sensor)
rP
Heating circuit 1 with mixer
rQ
Extension kit for one heating circuit with mixer with integral mixer motor
and
rW
Flow temperature sensor heating circuit M1
rE
Heating circuit pump, heating circuit M1
rR
3-way mixer
or
Divicon (with 3-way mixer and heating circuit pump)
tP
Heating circuit 2 with mixer
tQ
Extension kit for one heating circuit with mixer with integral mixer motor
and
(cont.)
Preparing for installation
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C3ha

Table of Contents