Technical specifications
Article number
Power loss
Power loss, typ.
Address area
Address space per module
•
•
Hardware configuration
Automatic encoding
•
Digital inputs
Number of digital inputs
Source/sink input
Input characteristic curve in accordance with IEC
61131, type 1
Input voltage
•
•
•
Input current
•
Input delay (for rated value of input voltage)
for standard inputs
for technological functions
Cable length
•
•
Interrupts/diagnostics/status information
Diagnostics function
Alarms
•
•
Diagnostics indication LED
•
•
66
Inputs
Outputs
Electronic coding element type F
Rated value (DC)
for signal "0"
for signal "1"
for signal "1", typ.
parameterizable
–
at "0" to "1", min.
–
at "0" to "1", max.
–
at "1" to "0", min.
–
at "1" to "0", max.
–
parameterizable
–
shielded, max.
unshielded, max.
Diagnostic alarm
Hardware interrupt
RUN LED
ERROR LED
6ES7136-6BA01-0CA0
2 W
7 byte; S7-300/400F CPU, 6 byte
5 byte; S7-300/400F CPU, 4 byte
Yes
Yes
8
Yes; P-reading
Yes
24 V
-30 to +5 V
+15 to +30 V
3.7 mA
Yes
0.4 ms
20 ms
0.4 ms
20 ms
No
1 000 m
500 m
Yes
Yes
No
Yes; green LED
Yes; red LED
Digital input module F-DI 8x24VDC HF (6ES7136-6BA01-0CA0)
Equipment Manual, 10/2021, A5E50578307-AA