Troubleshooting
Symptom
Blower motor inoperable.

LED Error Codes

The LED error codes are displayed on the control panel using the cycle and clean lights. Refer to the chart below to
determine the type of error that is being displayed.
Type of error
Latch
RTD
(Oven Probe)
Model
(The model header failure only occurs at power up of unit.
Cooling Fan
High limit
22
Possible Cause
Open blower motor.
Oven sensor out of calibration.
Open relay K8 or K9.
Open oven control board.
Defective oven wiring (shorted,
open, or burned).
LED Error Codes
Cycle Light
OFF
1 flash
2 flashes
Install correct header and restart power up.)
3 flashes
4 flashes
Corrective Action
Replace blower motor.
Replace oven sensor.
Replace oven control board.
Replace oven control board.
Repair or replace defective wiring.
Clean Light
1 flash
OFF
ON
ON
ON