Removal of Electrical Box
5. Removal of Electrical Box
Procedure
Step
1. Remove the electrical box.
Remove the electrical box
cover.
1
Remove the screws
and disconnect the
earth terminals (green /
yellow-striped wire
harness).
Release the room
2
temperature thermistor.
Disconnect the
connectors and
terminal strip for power
supply, all from the
power supply / control
PCB.
3
Remove the 4 fixing
screws off the electrical
box.
4
Pull out the electrical
box toward yourself.
10
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Green / Yellow
Terminal strip for
power supply
Room temperature
Clamp
thermistor
Screws
Earth terminal screws
(R18531)
Connectors
(R18532)
Screws
(R18523)
(R2464)
Si06-760
Points
The wire harnesses of the
connectors are tied up with
the clamp.
The room temperature
thermistor is fixed to the
holder.
Removal Procedure