Using The Control Keyboard - Jøtul PF 710 Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

Available languages

Available languages

7�1�2 Menu description
ICON
FUNCTION
Power
Ventilation:
*(if provided)
Temperature
Fuel
Time breaker switch
ICON
FUNCTION
SUBMENU
Adjustment
[10]
[11]
[12]
[13]
[14]
[15]
[30]
[31]
[40]
Submenu [30] and [40] and the Configuration menu are password protected and intended solely for the technical service.
7�2 USING THE CONTROL KEYBOARD
• Touching the arrow keys
menus, which are highlighted one by one.
• To change the settings of a given function, it is enough
to press the
button when the function is displayed
and change the value using the
Setting working power.
Setting of air fan power in room
Displays the room temperature and allows for programming the desired
temperature.
Displays the time of independent operation and enables zeroing of this
time during pellet loading [FULL] or deactivation of the display [OFF].
Activates and deactivates the time breaker switch. When the control clock
is engaged, the icon is displayed constantly.
Weekly scheduler
[1]
Programs
[2]
Clock/date
[3]
Hours remaining
[4]
System information
[5]
Inactive function
[6]
Eco function
[7]
Reignition delta
[8]
Anti-freeze protection
[9]
temperature
Keyboard lock
Screen brightness
Display mode
Sound signaller
volume
Pellet type
Inactive function
Fitter's menu
Manual worm loading Manual start-up of pellet loading system
Service menu
scrolls through different
keys.
DESCRIPTION
DESCRIPTION
Assignment of programs (max. 3) to different days
of the week.
Configuration of programs.
Setting the date and time.
Displays the number of hours remaining until the
next recommended maintenance. The "Hi" value
signifies a number greater than 999 hours.
Displays the current software version.
Activates or deactivates Eco mode, which enables
automatic firing and extinguishing depending on
ambient temperature (only in configuration 1).
The difference in degrees relative to room
temperature, below which the stove will reignite
(only in configuration 1).
The minimum temperature below which the stove
is fired up (only in configuration 1).
Configuration of button locking
Sets the brightness level of the screen.
Configuration of data display.
Setting of the sound signaller's volume.
3 different pellet types can be set.
Changes/displays stove configuration.
Menu intended for technical service.
• Press the
• In general, all flashing parameters can be changed
using the
it possible to cancel a change; pressing it for a long
time displays the code of the alarm that may have been
activated.
ENGLISH
VALUES
1–5
OFF*, 1–5; Auto; Hi.
from 6°C to 51°C
FULL – OFF
ON – OFF
VALUES
from [d1] to [d7]
from [P1] to [P6]
OFF; Eco
from 0,5°C to 5,0°C
OFF;
from 3°C to 20°C
OFF; Lo; Hi
OFF;
from 1 to 5
OFF;
from 1 to 4
OFF;
from 1 to 5
from 1 to 3
PWD: „54"
PWD: "54"
key again to confirm the change.
keys.The "Cancel" button
makes