ESAB HandyPlasma 35i Operating Manual page 24

Table of Contents

Advertisement

ELECTRODE OR NOZZLE INSTALLATION ERROR SCREEN
The electrode or cutting nozzle installation error screen is displayed when the electrode or cutting nozzle are
not installed correctly. The gas flows for 2 seconds and then stops for 3 seconds. The machine continues to
check the electrode and cutting nozzle situation until they are in the correct position.
Check or replace the worn cutting nozzle and electrode.
Figure 5.18 - Electrode or cutting nozzle installation error screen
AIR PRESSURE ERROR SCREEN
The air pressure error screen is displayed when the output air pressure is out of range. Adjust the compressed
air pressure between 6 and 8 bar. The error alarm will deactivate.
Figure 5.19 - Air pressure error screen
VOLTAGE ERROR SCREEN
The voltage error screen is displayed when the input voltage is very low or when the PFC circuit fails. In this case, it
is advisable to contact an ESAB Authorized Service Center to assess the equipment.
Figure 5.20 - Voltage error screen