Inspecting Pilot And Burner Flame Patterns; Cleaning And Maintenance - Superior Fireplaces BRT4336TEN-B Installation And Operation Instruction Manual

Custom series decorative в-vent fireplace, electronic ignition system
Hide thumbs Also See for BRT4336TEN-B:
Table of Contents

Advertisement

INSPECTING PILOT AND BURNER FLAME PATTERNS

Periodically check pilot flame pattern and burner flame patterns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the proper flame. Alterations
may have occurred during shipping and handling. The pilot is located
on the back right hand side of the burner.
The flame must envelope 1/4" of top of the igniter/sensor and ground-
ing stem.
If your pilot assembly does not meet these requirements:
• Turn adjustment screw marked PILOT clockwise to decrease or
counterclockwise to increase the flame to proper size (see Figure
37, Page 17). Do not remove adjustment screw.
• see Troubleshooting, Page 21
BURNER FLAME PATTERN
Burner flames will be steady, not lifting or floating. Flames should
go up through the middle of log set. Flames should not "spill" to the
edges of pan or sides of log set.
Figure 40 shows a typical flame pattern. If burner flame pattern dif-
fers from that described:
• turn appliance off (see To Turn Off Gas to Appliance, Page 17)
• see Troubleshooting, Page 21
Pilot
Burner
Figure 39 - Correct Pilot Flame Pattern
Figure 40 - Typical Flame Pattern
18
by a qualified service person. The appliance should
be inspected before each use and at least annually
by a qualified service person. More frequent cleaning
may be required due to excessive lint from carpeting,
bedding material, pet hair, etc. It is imperative that
the control compartments, burners and circulating air
system be kept clean.
cool.
servicing appliance.
opening(s) of the burner(s) clean may result in sooting
and property damage.
PILOT AND BURNER
• Remove logs and ember material before cleaning burner and replace
Sensing
when cleaning is complete.
Rod
• Burner and controls should be cleaned with compressed air to
remove dust, dirt or lint.
Igniter/
• Use a vacuum cleaner or small, soft bristled brush to remove excess
Sensor
dust, dirt or lint.
LOGS
• If you remove logs for cleaning, refer to log placement information
on Pages 13-14 to properly replace logs.
• Use a vacuum cleaner to remove any carbon buildup on logs.
• Replace log(s) if broken. See Replacement Parts, Page 20.
• Replace ember material periodically as needed. See Replacement
Parts, Page 20.
INSPECT VENTING SYSTEM
The appliance and venting system should be thoroughly inspected
before initial use and at least annually by a qualified service techni-
cian (inspection should include ensuring that venting system is
unobstructed and vent components are properly assembled and not
damaged). Homeowner must contact a qualified service technician
at once if any abnormal condition is observed.
If the venting system is disassembled for any reason, a qualified ser-
vice technician should follow vent installation instructions for proper
reassembly and proper sealing of the venting system components.
SuperiorFireplaces.us.com

CLEANING AND MAINTENANCE

WARNING: Installation and repair should be done
WARNING: The logs can be hot. Handle only when
WARNING: Turn off gas and electrical power before
WARNING: Failure to keep the primary air
900807-00E

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents