BURNER FLAME ADJUSTMENTS

WARNING
• Air shutter adjustment should
only be performed by a quali-
fied professional service tech-
nician.
• Ensure front glass panel are
in place and sealed during
adjustment.
CAUTION
• Soot will be produced if the
air shutter is closed too much.
Any damage due to sooting,
resulting from improperly
setting the air shutter, is not
covered under the warranty.
• The air shutter door and
nearby appliance surfaces
are hot. Exercise caution to
avoid injury while adjusting
flame appearance.
1. Refer to Figure 77, page 53 for proper flame
appearance. To adjust the flame, rotate the
adjustment rod toward the back or toward
the front of the fireplace (rod located in the
lower control area). Position the air shutter
to the factory setting as shown in the table
in Figure 78.
2. Light appliance (follow lighting procedure
on lighting label in control compartment or
see the Installation and Operation Manual).
3. Allow the burner to operate for at least 15
minutes while observing the flame continu-
ously to ensure that the proper flame ap-
pearance has been achieved. If the following
conditions are present, adjust accordingly.
• If flame appears weak or sooty, adjust
the air shutter, incrementally, to a more
open position until the proper flame
appearance is achieved.
• If flame remains blue, adjust the air
shutter, incrementally, to a more closed
position until the proper flame appear-
ance is achieved.
4. Leave the control knob (off/pilot/on) in the
ON position and the burner OFF/ON switch
OFF (and remote switches, if applicable).
5. When satisfied that the burner flame appear-
ance is normal, re-install the lower control
compartment door then proceed to finish
the installation.
54
Decrease Shutter Opening
In This Direction
Orifice
Increase Shutter Opening
In This Direction
Air Shutter
Adjusting Rod
Note - Burners are omitted in this view for clarity.
Main Burner Factory Air Shutter
Opening Setting - All Models
Model
Natural
Gas
1/8"
All Models
3.2mm
Adjustment Rod Positions
Figure 78
(when viewed from above)

Electronic Appliance Checkout

To light the burner, turn 'ON' the unit mounted
On/Off switch or the optional remote wall switch.
Ensure the igniter lights the pilot. The pilot
flame should engulf the flame rod as shown
in Figure 79.
ELECTRONIC
3/8 To 1/2 Inch
(9 mm to 13 mm)
Proper Flame
Adjustment
Pilot
Nozzle
Figure 79
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Installation and Operation Instructions
Propane
Gas
1/4"
6.4mm
Ground
Electrode
Flame Rod
Hot Surface
Igniter