Error 127

Error Message Displayed to user
E127
Condition
ECB and RCB base - Vsys power supply over voltage detection.
Cause
• Bad Vext brick power supply
• Bad ECB
Remedy
• Measure Vext to ensure rated V output. Vsys too high, replace brick power supply.
• Replace ECB