Error 76 - Life Fitness Integrity SL Service Manual

Hide thumbs Also See for Integrity SL:
Table of Contents

Advertisement

Error 76

Error Message Displayed to user
• E76
• System Error
Condition
Motor Controller detected a UL Error condition related to a hardware failure.
Cause
• Software update needed
• Bad Motor Controller
Remedy
• Ensure that latest software is installed. Download the latest software
https://www.halo.fitness/web/
softwareDownload.html.
• Replace Motor Drive Board / Motor Controller