Error 90 - Life Fitness Integrity SL Service Manual

Hide thumbs Also See for Integrity SL:
Table of Contents

Advertisement

Error 90

Error Message Displayed to user
• E90
• Notify Maintenance Steps Jammed
Keep error on screen until OK button pressed.
Condition
Maximum positive force exceeded error, as reported by Motor Controller. The drive system detected having to push
the steps excessively to maintain speed.
Cause
• Check for something jamming the steps.
Remedy
• Check for and remove entrapped objects by pushing steps backward by hand within 45 seconds of the jam.
Restarting the steps will reactivate the 45 sec un-jam period until cleared.
• Check for excessive step drag. Diagnose / repair as needed.
• Check motor wiring and phase continuity. Repair / replace as needed.