Cleaning and Maintenance

Daily Checks

If an alarm system is not part of the refrigeration installation, the temperature of each case should be checked on
a daily basis via the thermometer that may be located in the left hand side of the ceiling panel, or via another reliable
method.
The case temperature should be in the range of 0C - 2C for both case types.
Up to three separate readings may have to be taken to ensure the case temperature isn't being taken during a
defrost cycle (which would give a higher than desired reading).
If it is consistently outside this range, contact Hussmann or your service contractor.
Visually check the case for damage or spills and take appropriate remedial action.
Visually inspect drain strainer and drain for any debris which could result in the drains becoming blocked with the
possibility of spilling on the floor creating a slip hazard
If the cabinet is turned off during non trading hours ensure the cabinet is cleaned thoroughly to avoid bacterial
growth during off time.

Cleaning

A thorough cleaning and service of the case should be carried out by qualified refrigeration and electrical engineers on a
six monthly basis. Please contact your service contractor.
Cases should also be cleaned by store staff on at least a weekly basis; some cases may, however, require more frequent
cleaning.

Important Notes

Do not use hot water on cold glass surfaces as the glass may shatter and cause serious injury.
Do not use abrasive, solvent, ammonia or oil-based cleaners.
Do not use steam or a high-pressure system to clean the case.
When flushing the waste drain, do not use high-pressure water hoses and be careful not to introduce water faster
than the waste outlet/drain can drain it.

Cleaning Procedure

1. Turn off the cleaning switch. Isolate power and remove stock.
_________________________________________________________________________________________________________________________
Page 25
CAUTION
If any damaged electrical components are
identified during inspection isolate case
power and contact service contractor.
DC13 COLD PLATE