Case ends are normally fitted in the factory; however, they occasionally need to be attached to a case on-site. Use this
procedure when an end attaches to a single case and when it is common to two cases.
Ensure that correct and appropriate manual handling techniques are applied when fitting a patch end.
Cases must be sealed before attaching case ends. To seal cases, refer to sealing case joins on page 10.
SEQUENCE OF OPERATIONS
1. Carefully run a knife around the inside rim of the end trim, taking care not to scratch the case end stainless steel
surface, and remove the case end membrane.
2. Apply silicone around the perimeter of case E/Frame 10mm in from the edge plus apply to center of E/Frame and
line up the ends with the case. Red line in Fig 19 denotes the silicone application.
_________________________________________________________________________________________________________________________
Page 30
Wiring diagrams – Supplied with each case.
Product Engineering Datasheet – Supplied with each case.
Setting Table – Supplied with each case.
Attaching case ends
Top glass horizontal adjustment
Front glass door camber adjustment
Fig (19) Silicone application
DC13 COLD PLATE