Technical Datas; Repair Information - Cadel LORD 7 Installer Manual

Hide thumbs Also See for LORD 7:
Table of Contents

Advertisement

PROBLEM
CAUSE
Routine main-
Stove running and
tenance alert (it
display showing
does not block the
"SERVICE"
system)
8

TECHNICAL DATAS

8.1

REPAIR INFORMATION

Now we give some instructions for the Authorized Technician to take into consideration to have access to stove mechanical com-
ponents.
• For fuse replacement in the electric socket which stands on the back of the stove, extract the fuses to change with the aid of a
screwdriver for opening the shutter (see Fig. 66).
Proceed as follows:
• Remove the sides (see the dedicated chapters).
• After these operations you can have access at the following components: geared motor, ignition plug, ambient fan, fume fan,
ambient probe, fume probe, thermostat, electronic board, pressostat.
• For cleaning or replacemente of the auger it is necessary to unscrew the three bolt of the geared motor and to extract it, un-
screw the two screws lying under the geared motor of the auger, remove the hand rejector inside the hopper and then unscrew
the inner bolt of the auger. (see Fig. 67 Fig. 68).
• To assembly proceed at the contrary.
Fig. 67 - Remove the screws
32
SOLUTION
When this flashing message appears upon start-up, it means
that the preset operating hours have elapsed before mainte-
nance. Contact the service centre.
Fig. 66 - Shutter with fuses to remove
INTERVENTION
Fig. 68 - Remove the screw