3.7

CHIMNEY COMPONENTS

3.8

CHIMNEY FLUE CONNECTION

Your pellet stove works through a fume draught forced by a fan. It is obligatory to check that all pipes are realized in compliance
with the following regulation on material selection: EN 1856-1, EN 1856-2 e UNI/TS 11278. All must be effected by specialized
personnel or companies as provided by UNI 10683:2012.
• The connection between the appliance and the chimney flue should be short in order to favor the draught and to avoid con-
densation in the pipes.
• The fume conduit should be equivalent or longer than the outlet joint ones (Ø 80 mm).
• Some stove models are endowed with a lateral and/or back exhaust. Check that the unused exhaust is sealed with the plug
given with standard equipment.
STUFE A PELLET
Fig. 6 - Chimney components
LEGEND
Fig. 6
1
Chimney pot
2
Fume outlet
3
Chimney flue
4
Termal insulation
5
External wall
6
Chimney union
7
Fume pipe
8
Heat generator
9
Inspection door
10
T-union with inspection plug
7