NB: for good combustion, the depression values must be between + -5 Pa and the temperature values between + - 10°C.
6

SPECIAL MAINTENANCE

6.1

INTRODUCTION

For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.
• Fume outlet pipes (fume conduit + chimney flue + chimney pot) must always be cleaned, scrubbed and checked by an autho-
rized technician in compliance with local regulations, with the instructions of the manufacturer and those of your insurance
company.
• It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets and the electronical
elements checked at least once a year.
All these operations must be planned in time with your Autorized Technical Assistance Service.
• After a long ineffective time, before turning on the stove check if there are obstructions in the fume exhaust.
• If the stove had been using continuously and intensely, the whole system (chimney included), must be cleaned and checked
more frequently.
• In case of replacement of damaged pieces please ask for the original spare part at the Autorized Retailer.
6.2

FUME CONDUIT CLEANING

The exhaust system must be cleaned every 2/3 months.
• Remove the inspection lid of the T-union (see Fig. 55).
• Extract the ash which has accumulated in the inner.
• After cleaning repeat the operation in reverse order, checking the condition and efficiency of the gasket, and if necessary
replace it.
It is important to sealed the cap othrwise noxiuous fumes will propagate among the room.
6.3
FUME CONDUIT CLEANING
The exhaust system must be cleaned every 2/3 months.
Unscrew the side screws
Unscrew the Cap stopper
• Remove the inspection lid of the T-union (see ).