12

TECHNICAL DATAS

12.1 REPAIR INFORMATION

Now we give some instructions for the Authorized Technician to take into consideration to have access to stove mechanical com-
ponents.
• For fuse replacement in the electric socket which stands on the back of the stove, extract the fuses to change with the aid of a
screwdriver for opening the shutter (see Fig. 94).
Proceed as follows:
• Remove the frame (see the dedicated chapters).
• After these operations you can have access at the following components: geared motor, ignition plug, ambient fan, fume fan,
ambient probe, fume probe, thermostat, electronic board, pressostat.
• For cleaning or replacemente of the auger it is necessary to unscrew the three bolt of the geared motor and to extract it, un-
screw the two screws lying under the geared motor (vedi Fig. 95), of the auger, remove the hand rejector inside the hopper
and then unscrew the inner bolt of the auger. (vedi Fig. 96).To assembly proceed at the contrary.
Fig. 95 - Remove the screws
45
new RIVER IDRO T2 - TESIS Airtight T2 - MIRA T2 - MAYA idroT2
Fig. 94 - Shutter with fuses to remove
Fig. 96 - Remove the screw