Connection To The External Thermostat; Connection To The External Thermostat (Sweet - Perla - Cristal - One At - Beam At - Accent At - Sound - Chrome - Round); Measurement - Cadel LORD 7 Installer Manual

Hide thumbs Also See for LORD 7:
Table of Contents

Advertisement

• Scroll with the P3 key up to: Pr46 Enable Remote "Pr46 rEMoto EnAbLEd ".
• Press the P1 or P2 key to modify the status.
• Confirm with the P3 key.
• Scroll to MB Output "Mb EScAPE " with key P1 or P2.
• Confirm with P3 key.
• Press P1 (temperature setting) and set t-e "t-e" value. The external thermostat is now enabled.
5.19 CONNECTION TO THE EXTERNAL THERMOSTAT (SWEET
AT - ACCENT AT - SOUND - CHROME - ROUND)
The stove works through a thermostat probe placed in its inner. If you desire, the stove can be connected to an external room
thermostat. This operation must be executed by an authorized technician.
Connect the wires from the external thermostat to the "Term opt" terminal on the stove board. Activate the external thermostat
(default setting OFF) as indicated below:
• Press the "menu" button.
• Scroll with the arrows to "Settings".
• Select by pressing "menu".
• Scroll with the arrows again to "Ext.Thermostat".
• Select by pressing "menu".
• Press the - + buttons.
• To activate the external thermostat select "on".
• Press the "menu" button to confirm.
5.20 STOVE CALIBRATION AND DEPRESSION MEASUREMENT
This stove has a pickup point positioned on the tank in order to measure the depression of the combustion chamber and verify its
proper operation.
To do this, proceed as follows:
• Connect a digital pressure switch with a tube to detect the negative pressure (see ).
• Load the feed screw via appropriate function.
• Start the stove and set "Set flame" to power 1 (the start-up time of this stove lasts between 8 and 10 minutes to ensure mini-
mum draught).
• Compare the read values with those on the table.
• Change power every 10 minutes and wait for it to stabilise.
• Access the user menu and, if necessary, change the parameters.
Fig. 53 - Casing removal
DATA
P1
Stove depression -
temperature 5 kW 25/26 Pa - 190°C
Stove depression -
temperature 7 kW 25/26 Pa - 190°C
STUFE A PELLET
Fig. 54 - Digital pressure switch connection
P2
P3
29/30 Pa - 185°C
31/32 Pa - 195°C
29/30 Pa - 200°C
34/35 Pa - 220°C
- PERLA
- CRISTAL
3
3
3
P4
35/36 Pa - 210°C
40/41 Pa - 240°C
- ONE AT - BEAM
P5
38/39 Pa - 220°
47/48 Pa - 250°
25