The connections to the terminal board must be made with cables with a maximum length of 3 metres (regardless
of whether they are signal or power cables).
Fig. 72 - Connections
- The water manostat cables that are prearranged in the boiler must be connected to the
hydraulic kit (optional).
- The flow switch cables are prearranged in the boiler for connection to the hydraulic kit (op-
tional) with domestic water.
REAR PANEL
If maintenance must be performed on a component of the stove, the rear panel can be removed (if the distances from the walls
allow it), otherwise, the maintenance can be performed by removing the side of the stove.
To remove the rear panel, remove the seven rear screws "a" and pull panel "L" away.
The "L" panel can also be removed with the stove installed since its shape corresponds with the smoke outlet pipe. Plate "L1" sup-
ports the flue pipe as it is secured to the stove using the two screws "a". With the stove installed you must only remove plate "L1" if
the smoke pipe must be removed, otherwise remove only plate "L".
9

SPECIAL MAINTENANCE

9.1

INTRODUCTION

For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.
• Fume outlet pipes (fume conduit + chimney flue + chimney pot) must always be cleaned, scrubbed and checked by an autho-
rized technician in compliance with local regulations, with the instructions of the manufacturer and those of your insurance
company.
• If there are no local regulations and no instruction from your insurance company, it is necessary to have your fume pipe, chim-
ney flue and chimney pot cleaned at least once a year.
• It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets and the electronical
elements checked at least once a year.
All these operations must be planned in time with your Autorized Technical Assistance Service.
35
new RIVER IDRO T2 - TESIS Airtight T2 - MIRA T2 - MAYA idroT2
z
W
Fig. 74 - back panel
Fig. 73 - Connections