Connection To The External Thermostat; (Amaranto 9 - Elane 9); Measurement - Cadel AMARANTO 9 Installer Manual

Hide thumbs Also See for AMARANTO 9:
Table of Contents

Advertisement

Fig. 67 - Electric socket with master switch
• Do not use extension cables.
• If the feeder cable is damaged, it must be replaced by an authorized technician.
• When the stove is not going to be used for a long period of time, it advisable to remove the plug from the socket on the wall.
• An electrical connection to a UPS/ACCUMULATOR/ STABILISER must guarantee a voltage of at least 210 V without power
surges. Considering the variety of UPS on the market regarding size and construction qualities, we cannot guarantee operation
once the stove is connected to these devices.
6.16 CONNECTION TO THE EXTERNAL THERMOSTAT (CRISTAL 9 - CRISTAL PLUS 9 - ICON PLUS 9 -
LIFE 9 - STEEL 9)
The stove works through a thermostat probe placed in its inner. If you desire, the stove can be connected to an external room
thermostat. This operation must be executed by an authorized technician.
Connect the wires from the external thermostat to the "Term opt" terminal on the stove board. Activate the external thermostat
(default setting OFF) as indicated below:
• Press the "menu" button.
• Scroll with the arrows to "Settings".
• Select by pressing "menu".
• Scroll with the arrows again to "Ext.Thermostat".
• Select by pressing "menu".
• Press the - + buttons.
• To activate the external thermostat select "on".
• Press the "menu" button to confirm.
6.17 CONNECTION TO THE EXTERNAL THERMOSTAT (AMARANTO 9 - ELANE 9)
The stove works through a thermostat probe placed in its inner. If you desire, the stove can be connected to an external room
thermostat. This operation must be executed by an authorized technician.
Connect the wires from the external thermostat to the "Term opt" terminal on the stove board. Activate the external thermostat
(default setting OFF) as indicated below:
• Press the menu key for a few seconds (1).
• Repeatedly press the P2 key until M8 - Technical settings "M8-SEt tEcHnic " appears.
• Select by pressing the P3 key.
• Set the password with keys P1 or P2 (keeping the key pressed accelerates the setting).
• Confirm by pressing the P3 key.
• Press the P1 or P2 keys until M8 - 2 General settings "M8-2 SEt GEnErAL" appears.
• Confirm with P3.
• Scroll with the P3 key up to: Pr46 Enable Remote "Pr46 rEMoto EnAbLEd ".
• Press the P1 or P2 key to modify the status.
• Confirm with the P3 key.
• Scroll to MB Output "Mb EScAPE " with key P1 or P2.
• Confirm with P3 key.
• Press P1 (temperature setting) and set t-e "t-e" value. The external thermostat is now enabled.
6.18 STOVE CALIBRATION AND DEPRESSION MEASUREMENT
This stove has a pickup point positioned on the tank in order to measure the depression of the combustion chamber and verify its
proper operation.
To do this, proceed as follows:
• Connect a digital pressure switch with a tube to detect the negative pressure (see Fig. 69 Fig. 70).
• Load the feed screw via appropriate function.
• Start the stove and set "Set flame" to power 1 (the start-up time of this stove lasts between 8 and 10 minutes to ensure mini-
mum draught).
CRISTAL 9 - CRISTAL PLUS 9 - ICON PLUS 9 - AMARANTO 9 - LIFE 9 - STEEL 9 - ELANE 9