B Bar Code Magnification; C Set Column Offset Amount - Datamax A-4310 Programmer's Manual

Class series
Hide thumbs Also See for A-4310:
Table of Contents

Advertisement

B
Bar Code Magnification
(Display-Equipped Models only)
This command provides a mechanism to specify bar codes greater than 36 dots (0-9,A-Z in the field
record). The value is reset to 1 at the start of every label and stays active for the entire label or set to
a new value.
Syntax:
Where:
Sample:
The sample instructs the printer to print two bar codes, each 9 dots by 3 dots.
C
Set Column Offset Amount
This command allows horizontal adjustment of the point where printing begins. The printer is
instructed to print label formats nnnn units to the right of the position that the format specifies. This
feature is useful when a single format is to be printed on labels containing preprinted information.
Note: If using preprinted labels where the placement of the preprint data varies from label to label, the
printed information may overlap the preprinted data.
Syntax:
Where:
Sample:
The sample shifts all format data 0.5 inches to the right, unless the printer is in metric mode, (see
Label Formatting Command 'm').
Class Series Programmer's Manual
Label Formatting Command Functions
Bnn
-
Is a two digit decimal number indicating the magnification
nn
value.
<STX>L<CR>
D11
B01
1a9305000100030ABCD<CR>
B03
1a3105000700030ABCD<CR>
Q0001
E
Cnnnn
-
Is a four-digit number for the column offset, inches/100 or
nnnn
mm/10. The printer default is 0 for offset.
<STX>L
C0050
141100001000100DATAMAX<CR>
111

Hide quick links: