  • Page 1 These Instructions are Brief Operating Instructions; they are not a substitute for the Operating Instructions pertaining to the device. For detailed information, refer to the Operating Instructions and other documentation. Available for all device versions via: • Internet: www.endress.com/deviceviewer • Smart phone/Tablet: Endress+Hauser Operations App...
  • Page 2 Gammapilot M FMG50 Order code: XXXXX-XXXXXX Ser. no.: XXXXXXXXXXXX Ext. ord. cd.: XXX.XXXX.XX Serial number www.endress.com/deviceviewer Endress+Hauser Operations App A0023555 Endress+Hauser...
  • Page 3: Table Of Contents

    Contact addresses at Endress+Hauser ........
  • Page 4: About This Document

    About this document Gammapilot M FMG50 Certificates ................36 CE mark .
  • Page 5: Documentation

    For an overview of the scope of the associated Technical Documentation, refer to the following: • W@M Device Viewer (www.endress.com/deviceviewer): Enter the serial number from nameplate • Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the 2D matrix code (QR code) on the nameplate 1.2.1 Technical Information (TI)
  • Page 6: Registered Trademarks

    Bluetooth® The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by Endress+Hauser is under license. Other trademarks and trade names are those of their respective owners. Basic safety instructions...
  • Page 7: Designated Use

    Gammapilot M FMG50 Basic safety instructions • Being instructed and authorized according to the requirements of the task by the facility' s owner-operator • Following the instructions in these Operating Instructions Designated use The Gammapilot FMG50 is a compact transmitter for non-contact level, point level, density and concentration measurement.
  • Page 8: Radiation Protection

    Basic safety instructions Gammapilot M FMG50 WARNING ‣ Observe the safety instructions associated with the device. These instructions depend on the certificate ordered. Radiation protection The Gammapilot FMG50 is used in conjunction with a radiation source, contained in a source container.
  • Page 9: Workplace Safety

    Gammapilot M FMG50 Basic safety instructions Shielding Ensure the best possible shielding between the radiation source and yourself and all other persons. Effective shielding is provided by source containers (FQG60, FQG61/ FQG62,FQG63, FQG66) and all high-density materials (lead, iron, concrete etc.).
  • Page 10: Product Safety

    The measuring system meets the legal requirements of the applicable EU Directives. These are listed in the corresponding EU Declaration of Conformity along with the standards applied. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. 2.8.2 EAC conformity The measuring system meets the legal requirements of the applicable EAC guidelines.
  • Page 11 ‣ Enter the serial number from the nameplate into the Endress+Hauser Operations App or use the Endress+Hauser Operations App to scan the 2-D matrix code (QR Code) provided on the nameplate  All the information about the measuring device and the scope of the associated Technical Documentation are displayed.
  • Page 12: Installation Conditions

    Mounting Gammapilot M FMG50 Installation conditions 3.2.1 General information • The angle of emission of the source container must be exactly aligned to the measuring range of the Gammapilot FMG50. Observe the measuring range marks of the device. • The source container and the Gammapilot FMG50 should be mounted as close to the vessel as possible.
  • Page 13 Gammapilot M FMG50 Mounting • Version PVT 800 : Total length A: 1 190 mm (46.85 in), weight: 15.54 kg (34.26 lb) • Version PVT 1200 : Total length A: 1 590 mm (62.60 in), weight: 17.94 kg (39.55 lb) •...
  • Page 14 Mounting Gammapilot M FMG50 Examples A0037715 Vertical cylinder; the Gammapilot FMG50 is mounted vertically with the detector head pointing either downwards or upwards, the gamma ray is aligned to the measuring range. Correct: Gammapilot FMG50 mounted outside the tank insulation...
  • Page 15 • If only horizontal pipes are accessible, the path of the beam should also be arranged horizontally to minimize the influence of air bubbles and deposits. • The Endress+Hauser clamping device or an equivalent clamping device should be used to fasten the source container and the Gammapilot FMG50 to the measuring pipe.
  • Page 16 Mounting Gammapilot M FMG50 A0018076 Vertical beam (90°) Diagonal beam (30°) Measurement section Sample point • To increase the accuracy of density measurements, the use of a collimator is recommended. The collimator screens the detector against background radiation. • When planning, the total weight of the measuring system must be taken into consideration.
  • Page 17 • If only horizontal pipes are accessible, the path of the beam should also be arranged horizontally to minimize the influence of air bubbles and deposits. • The Endress+Hauser clamping device or an equivalent clamping device should be used to fasten the source container and the Gammapilot FMG50 to the measuring pipe.
  • Page 18 Therefore, it is advisable to use diagonal irradiation or a measurement section for small pipe diameters. For the configuration of the measuring system, please contact your Endress+Hauser sales organization or use the Applicator™ configuration program.
  • Page 19 Gammapilot M FMG50 Mounting received is proportional to the concentration of the radiating medium in the conveyed material. 3.2.10 Installation conditions for flow measurement Measurement of mass flow (liquids) The density signal determined by the Gammapilot FMG50 is transmitted to the Promag 55S.
  • Page 20: Post-Installation Check

    Electrical connection Gammapilot M FMG50 A0036637 Gammapilot FMG50 Post-installation check After installing the measuring device, carry out the following checks:  Is the device damaged (visual inspection)?  Does the device match the measuring point specifications (ambient temperature, measuring range etc.)? ...
  • Page 21: Terminal Assignment

    Gammapilot M FMG50 Electrical connection A0028908  2 Block diagram of HART connection Device with HART communication HART resistor Power supply The HART communication resistor of 250 Ω in the signal line is always necessary in the case of a low-impedance power supply.
  • Page 22: Cable Entries

    Electrical connection Gammapilot M FMG50 Cable entries A0038156 Cable entry Dummy plug The number and type of cable entries depend on the device version ordered. The following are possible: • M20 threaded joint, plastic, IP66/68 NEMA Type 4X/6P • M20 threaded joint, nickel-plated brass, IP66/68 NEMA Type 4X/6P •...
  • Page 23: Rated Cross-Section

    Gammapilot M FMG50 Electrical connection CAUTION ‣ Please refer to the separate documentation on applications in hazardous areas for the safety instructions For optimum electromagnetic compatibility, the potential matching line should be as short as possible and at least 2.5 mm (14 AWG) in cross-section.
  • Page 24: Operation

    Operation via FieldCare/DeviceCare FieldCare/DeviceCare is an Endress+Hauser asset management tool based on FDT technology. With FieldCare/DeviceCare you can configure all Endress+Hauser devices as well as devices from other manufacturers that support the FDT standard. Hardware and software requirements can be found on the Internet: www.de.endress.com ->...
  • Page 25: Alternative Operation Options

    Gammapilot M FMG50 Operation FieldCare supports the following functions: • Configuration of transmitters in online mode • Loading and saving device data (upload/download) • Documentation of the measuring point Connection options: • HART via Commubox FXA195 and USB interface of a computer •...
  • Page 26 A0038834  5 DeviceCare/FieldCare via service interface (CDI) Computer with DeviceCare/FieldCare operating tool Commubox FXA291 Service interface (CDI) of the measuring device (= Endress+Hauser Common Data Interface) 5.2.3 Operation via RIA15 A0017719  6 Display and operating elements of the process indicator...
  • Page 27 Gammapilot M FMG50 Operation Enter key; for calling up the operating menu, confirming the selection/configuration of parameters in the operating menu Selection and configuration/changing of values in the operating menu; pressing the ' + ' and ' - ' keys simultaneously takes the user back up a menu level. The configured value is not saved.
  • Page 28: Locking/Unlocking Configuration

    Operation Gammapilot M FMG50 5.2.5 Heartbeat Verification/Monitoring Heartbeat submenu is only available if operating via FieldCare or DeviceCare. It contains wizards that are available with the Heartbeat Verification and Heartbeat Monitoring application packages. SD02414F Locking/unlocking configuration 5.3.1 Software locking Locking via password in FieldCare / DeviceCare / Smartblue Access to the configuration of the FMG50 can be locked by assigning a password.
  • Page 29: Commissioning

    Gammapilot M FMG50 Commissioning Open the device in FieldCare or DeviceCare.  The dashboard (homepage) of the device is displayed: Click "System -> Device management" Reset the device in the "Device reset" parameter The following types of reset can be selected: •...
  • Page 30: Commissioning Using The Commissioning Wizard

    Requirements Device requirements Commissioning via SmartBlue is only possible if the device has a Bluetooth module. FieldCare and DeviceCare are available for download at www.software-products.endress.com. To download the software, it is necessary to register in the Endress+Hauser software portal. Endress+Hauser...
  • Page 31: Commissioning Via On-Site Operation

    Gammapilot M FMG50 Commissioning SmartBlue system requirements SmartBlue is available as download for Android devices from the Google Play Store and for iOS devices from the iTunes Store. • Devices with iOS: iPhone 4S or higher from iOS9.0; iPad2 or higher from iOS9.0; iPod touch 5th generation or higher from iOS9.0...
  • Page 32 Commissioning Gammapilot M FMG50 Zero/I Alarm Span/II Display A0039285 Operating key for empty calibration (function I) Operating key for full calibration (function II) DIP switch for alarm current (SW-defined/Min. alarm) DIP switch for locking and unlocking the measuring device • Empty calibration: Press and hold the operating key for empty calibration (I) > 3 s •...
  • Page 33: Operation And Settings Via Ria15

    Gammapilot M FMG50 Commissioning Operation and settings via RIA15 See the RIA15 Operating Instructions, BA01170K Data access - Security 6.6.1 Locking via password in FieldCare / DeviceCare / Smartblue The Gammapilot FMG50 can be locked and unlocked via a password (see the "Software locking"...
  • Page 34: Maintenance And Repair

    Repair 7.2.1 Repair concept Under the Endress+Hauser repair concept, devices have a modular design and repairs are carried out by Endress+Hauser Service or by properly trained customers. Spare parts are grouped into logical kits with the associated replacement instructions. For more information on service and spare parts, please contact Endress+Hauser Service.
  • Page 35: Spare Parts

    (WEEE), our products are marked with the depicted symbol in order to minimize the disposal of WEEE as unsorted municipal waste. Such products may not be disposed of as unsorted municipal waste and can be returned to Endress+Hauser for disposal at conditions stipulated in our General Terms and Conditions or as individually agreed.
  • Page 36: Contact Addresses At Endress+Hauser

    Certificates and approvals Gammapilot M FMG50 Battery disposal Dispose of batteries according to local regulations. Recycle used batteries wherever possible. Contact addresses at Endress+Hauser Contact addresses are available at www.endress.com/worldwide or from your local Endress +Hauser branch office. Certificates and approvals The availability of approvals and certificates can be called up daily via the Product Configurator.
  • Page 37 Instruments -> Select device -> Advanced function: Product Configurator CE mark The measuring system meets the legal requirements of the EU Directives. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. Approval for EAC is pending...