York YVAA Style A Installation Operation & Maintenance page 163

Air-cooled screw liquid chiller
Table of Contents

Advertisement

Form 201.28-NM1.1
Issue date: 08/06/2021
CONDENSER FANS ON
CONDENSER FAN SPEED
COMPRESSOR HEATER
VI STEP SOLENOID 1
VI STEP SOLENOID 2
RUN PERMISSIVE
VSD RUN RELAY
VSD SOFTWARE RUN SIGNAL
SYSTEM 2 DATA
COMPRESSOR STATUS
RUN TIME
MOTOR CURRENT
SUCTION PRESSURE
DISCHARGE PRESSURE
OIL PRESSURE
CONDENSER LIQUID TEMP
DISCHARGE TEMPERATURE
SAT CONDENSER TEMP
SUBCOOLING
SAT DISCHARGE TEMP
DISCHARGE SUPERHEAT
MOTOR TMP
XXX.X XXX.X XXX.X DEGF
COMPRESSOR SPEED
FLASH TANK LEVEL
COND DRAIN % OPEN
ECONOMIZER % OPEN
CONDENSER FANS ON
CONDENSER FAN SPEED
COMPRESSOR HEATER
VI STEP SOLENOID 1
VI STEP SOLENOID 2
RUN PERMISSIVE
VSD RUN RELAY
VSD SOFTWARE RUN SIGNAL
UNIT OPERATING SCHEDULE
S
M
T
W
T
F
S
MON START=00:00AM
TUE START=00:00AM
WED START=00:00AM
THU START=00:00AM
FRI START=00:00AM
JOHNSON CONTROLS
0
XXX % (vsd)
ON
OFF
OFF
ON
OFF
OFF
ON
0-0-15-26 D-H-M-S
104 AMPS
87 %FLA
57 PSIG
233 PSIG
218 PSIG
42.9 DEGF
145.5 DEGF
31.7 DEGF
11.2 DEGF
112.1 DEGF
33.4 DEGF
XXX.X%
< 512 ADC
XXX.X%
XXX.X%
3
XXX% (vsd)
OFF
OFF
OFF
ON
OFF
OFF
*=HOLIDAY
STOP=00:00AM
STOP=00:00AM
STOP=00:00AM
STOP=00:00AM
STOP=00:00AM
SAT START=00:00AM
HOL START=00:00AM
SOUND LIMIT SCHEDULE
(if enabled)
MON START=00:00AM
TUE START=00:00AM
WED START=00:00AM
THU START=00:00AM
FRI START=00:00AM
SAT START=00:00AM
HOL START=00:00AM
History data printout
History printouts, when selected, provide stored data
relating to all specific system and chiller operating
conditions at the time of the fault, regardless of wheth-
er a lockout occurred. History information is stored in
battery-backed memory on the Chiller Control Board
and is not affected by power failures or resetting of
faults. Whenever a fault of any type occurs, all system
operating data is stored in battery-backed memory at
the instant of the fault. The history printout is similar
to the operating data printout except for the change in
the header information shown as follows:
YORK INTERNATIONAL CORPORATION
YVAA SCREW CHILLER
HISTORY NUMBER 1
2:04:14 PM
SYS 1 YYYYYYY
HIGH DSCH PRESS SHUTDOWN
STATUS AT TIME OF SHUTDOWN
SYS 1 XXXXXXXXXXXXXXXXXXXXXXXXXX
SYS 2 XXXXXXXXXXXXXXXXXXXXXXXXXX
ALL FAULTS
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
The most recent fault will always be stored as
HISTORY BUFFER #1.
SECTION 8 - MICROPANEL
STOP=00:00AM
STOP=00:00AM
STOP=00:00AM
STOP=00:00AM
STOP=00:00AM
STOP=00:00AM
STOP=00:00AM
STOP=00:00AM
STOP=00:00AM
30 APR 11
163
8

Advertisement

Table of Contents
loading

Table of Contents