Table 29. Noise levels (Declared A-weighted sound pressure level, L
Product description
8202-E4D single-socket processor,
rack-integrated configuration, two
power supplies, and six hard disk
drives.
8202-E4D single-socket processor, two
power supplies, six hard disk drives,
and stand-alone system feature code
(7572)
8202-E4D single-socket processor,
rack-integrated configuration, two
power supplies, low profile PCIe
riser card, and six hard disk drives
8202-E4D single-socket processor,
rack-integrated configuration, two
power supplies, six hard disk drives,
and acoustic mode off.
8202-E4D single-socket processor,
rack-integrated configuration, one
power supply, and six hard disk
drives
8202-E4D single-socket processor,
rack-integrated configuration, one
power supply, six hard disk drives,
and low profile PCIe riser card.
Table 30. Test parameters for measurements
Test parameters
Test voltage and frequency
Total harmonic distortion of the electricity
supply system
Information and documentation on the
instrumentation setup and circuits that are used
for electrical testing
Measurement methodology that is used to
determine information in this document
Power 740 Express (Machine Type: 8205) Technical Documentation for EU
Regulation 617/2013
International Business Machines Corporation
New Orchard Road
Armonk, New York 10504
http://www.ibm.com/customersupport/
For more information, see http://www-03.ibm.com/systems/power/hardware/energy-star/.
Table 31. System characteristics
System characteristics
Product type
22
Site and hardware planning
Declared A-weighted sound pressure level, L
40
39
47
49
51
52
Properties
230 V ac at 50 Hz or 60 Hz
The maximum harmonic content of the input voltage waveform is
equal to or less than 2%. The qualification is compliant with EN
61000-3-2.
ENERGY STAR Test Method for Computer Servers; ECOVA
Generalized Test Protocol for Calculating the Energy Efficiency of
Internal Ac-Dc and Dc-Dc Power Supplies
ENERGY STAR Servers Version 2.0 Program Requirements;
ECOVA Generalized Test Protocol for Calculating the Energy
Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies
Properties
Computer server
) (continued)
pAm
(dB)
pAm
38
37
47
49
51
52