Table 59. Temperature requirements
Operating
10°C - 38°C (32°F - 100.4°F)
Table 60. Environment requirements
Properties
Operating
Noncondensing
Recommended:
humidity
34% - 54%
Allowable: 20% -
80%
Table 61. Service clearances
Front
915 mm (36 in.)

5886 expansion unit

Hardware specifications provide detailed information for your expansion unit, including dimensions,
electrical, power, temperature, environment, and service clearances.
Table 62. Dimensions for rack-mounted expansion unit
Weight (with no drives
installed)
17.7 kg (39 lb)
Table 63. Electrical
Electrical characteristics
1
kVA
Rated voltage and frequency
1
Thermal output
Power requirements (maximum)
Power factor
Inrush current
Leakage current (maximum)
Phase
1
All measurements made in conformance with ISO 7779 and declared in conformance with ISO 9296.
Table 64. Temperature requirements
Operating
1
10 - 38°C (50 - 100.4°F)
1
The maximum 38°C (100.4°F) temperature must be derated 1°C (1.8 °F) per 137 m (450 ft) above 1295 m (4250 ft).
Storage
1°C - 60°C (33.8°F - 140°F)
Nonoperating
5% - 80%
Back
915 mm (36 in.)
Width
445 mm (17.5 in.)
Shipping
-40°C to 60°C (-40°F to 140°F)
Storage
Shipping
5% - 80%
5% - 100%
Sides
914 mm (36 in.)
Depth (including front
bezel)
521 mm (20.5 in.)
Properties
0.358
100 - 240 V ac at 50 - 60 Hz
1160 Btu/hr
340 W
0.95
55 A per power cord
3.10 mA
1
Nonoperating
-40 - 60°C (-40 - 140°F)
Maximum
altitude
3048 m (10 000 ft)
Height
89 mm (3.5 in.)