Systems Director Management Console specifications

IBM Systems Director Management Console (SDMC) specifications provide detailed information for your
SDMC, including dimensions, electrical, power, temperature, environment, and service clearances.
7042-CR6 rack-mounted Systems Director Management Console
specifications
Hardware specifications provide detailed information for your IBM Systems Director Management
Console (SDMC), including dimensions, electrical, environmental requirements, and noise emissions.
The SDMC controls managed systems, including the management of logical partitions and the use of
capacity on demand. Using service applications, the SDMC communicates with managed systems to
detect, consolidate, and send information to IBM for analysis. The SDMC provides service technicians
with diagnostic information for systems that can operate in a multiple-partitioned environment.
Use the following specifications to plan for your SDMC.
Table 127. Dimensions
Width
440 mm (17.3 in.)
Table 128. Electrical requirements
Electrical characteristics
Maximum measured power
Maximum kVA
Minimum thermal output
Maximum thermal output
Input voltage low range
Input voltage high range
Frequency (Hertz)
Table 129. Environmental requirements
Environment
Recommended operating temperature
Nonoperating temperature
Maximum altitude
Operating humidity
Nonoperating humidity
Table 130. Noise emissions (maximum configuration)
L
WAd
1
These levels were measured in controlled acoustical environments according to the procedures specified by the
American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296.
Actual sound-pressure levels in a specific location might exceed the average values stated because of room
reflections and other nearby noise sources. The declared sound-power levels indicate an upper limit, below which a
large number of computers will operate.
70
Site and hardware planning
Depth
711 mm (28.0)
1
Idling
6.1 bels
Height
43 mm (1.7 in.)
Properties
675 W
0.7 kVA
662 BTU/hr
2302 BTU/hr
100 V ac - 127 V ac
200 V ac - 240 V ac
47 Hz - 63 Hz
Temperature
10°C - 35°C (50°F - 95°F)
5°C - 45°C (41°F - 113°F)
3048 m (10000 ft)
8% - 80%
20% - 80%
Operating
6.1 bels
Weight (maximum
configuration)
15.9 kg (35.1 lb)