Table 48. Environment requirements
Environment
Operating
Noncondensing
8% - 80%
humidity
Wet bulb
23°C (73.4°F)
4
temperature
The upper limit of the wet bulb temperature must be derated 1°C per 274 m (900 ft) above 305 m (1000 ft).
Table 49. Noise emissions
Properties
L
WAd
<L
>
pA
m
Table 50. Service clearances
Front
915 mm (36 in.)
Related information:
Acoustics

5802 expansion unit

Hardware specifications provide detailed information for your expansion unit, including dimensions,
electrical, power, temperature, environment, and service clearances.
Table 51. Dimensions for rack-mounted expansion unit
Maximum configuration
weight
54 kg (120 lb)
Table 52. Electrical
Electrical characteristics
kVA (maximum)
Rated voltage and frequency
Thermal output (maximum)
Power requirements (maximum)
Power factor
Leakage current (maximum)
Phase
Plug type (Canada and U.S.)
Power cord length
Table 53. Temperature requirements
Operating
10°C - 38°C (32°F - 100.4°F)
Nonoperating
8% - 80%
27°C (80.6°F)
Operating
6.2 bels
44 dB
Back
915 mm (36 in.)
Width
444.5 mm (17.5 in.)
Storage
1°C - 60°C (33.8°F - 140°F)
Storage
5% - 80%
29°C (84.2°F)
Idle
6.1 bels
43 dB
Sides
915 mm (36 in.)
Depth
711.2 mm (28 in.)
Properties
.768 kVA
100 - 127 V ac or 200 - 240 V ac at 50 - 60Hz
2542 BTU/hr
745 W
.97
3.5 mA
Single
26
14 ft
Shipping
-40°C to 60°C (-40°F to 140°F)
Maximum altitude
3048 m (10 000 ft)
Height
4U