Omron E8F2 Manual page 20

Pressure sensor
Hide thumbs Also See for E8F2:
Table of Contents

Advertisement

E8F2
ON- and OFF Set Value Check Function
or
Measurement
mode
The ON and OFF points presently set can be checked.
Press the Up or Down Key in measurement mode to display the OUT1 ON point and on alternately.
Press the Up or Down Key again to display the OUT1 OFF point and off alternately.
Press the Up or Down Key after the above to display the OUT2 items.
If no key is input for approximately 2 s during the above operation, the present measurement value will be displayed automatically.
Dimensions
Unit: mm (inch)
J CONTROLLER
E8F2
With Mounting Bracket
or
Displayed
alternately
OUT1 ON point
OUT1 OFF point
28 (1.10)
Display panel
27 (1.06)
28
(1.10)
27
(1.06)
20.5
(0.81)
27 (1.06)
42
(1.65)
15
(0.59)
ON- and OFF-point Set value
or
or
Displayed
alternately
OUT2 ON point
29
17
1.5
(1.14)
(0.67)
(0.06)
Pressure-introducing
25.5 (1.00)
9
2
8
section
(0.35)
(0.31)
(0.68)
1/8 NPT
Vinyl-insulated round cable with five
conductors, 4 dia. (0.08 dia. x 30);
standard length: 2 m
6 (0.24)
Mounting Dimensions
15
29
(0.59)
(1.14)
5.4
(0.21)
28
(1.10)
21
or
Displayed
Displayed
alternately
alternately
OUT2 OFF point
Two-M3 (Depth: 6)
20
(0.79)
20
(0.79)
Two-M3
20.5
(0.81)
20
(0.79)
20
(0.79)
E8F2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents