Omron E8F2 Manual page 13

Pressure sensor
Hide thumbs Also See for E8F2:
Table of Contents

Advertisement

E8F2
Auto-teaching
Auto-teaching allows input measured values to be input as ON- and OFF-point set values instead of key input. One- or two-point auto-
teaching can be selected.
One-point teaching
ON
OFF
Pressure
value
Note: Auto-teaching will be possible if a is selected in the pressure setting method selection in basic setting mode.
1. Press the SET key to set the E8F2 to pressure setting mode and to display OUT1 and t.h1.
2. Press the Up or Down key to select the one-point teaching or two-point teaching method of OUT1 and OUT2.
Setting item
Measurement
mode
OUT1 OUT2kPa Torr Psi
OUT1 two-point teaching
OUT1 OUT2 kPa Torr Psi
t.h1: Teach hysteresis mode at first point
t.w: Teach window mode
Two-point Teaching (Hysteresis-mode Teaching)
OUT1
OUT1 OUT2 kPa Torr Psi
1. Press the SET key under condition 1 below while t.h1 is displayed to display the present measurement value.
2. Check the measurement value and press the Set key to perform and complete teaching the first point.
3. Press the Set key under condition 2 below to display the present measurement value.
Two-point teaching
ON
OFF
Pressure
value
OUT1 one-point teaching
OUT1 OUT2
kPa Torr Psi
Present measurement
value is displayed.
OUT1 OUT2 kPa Torr Psi
(This list of steps continues on the next page.)
Auto-teaching
OUT2 two-point teaching
OUT1 OUT2 kPa Torr Psi
OUT1 OUT2 kPa Torr Psi
14
E8F2
OUT2 one-point teaching
OUT1 OUT2kPa Torr Psi
Present measurement
value is displayed.
OUT1 OUT2 kPa Torr Psi

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents