Omron E8F2 Manual page 17

Pressure sensor
Hide thumbs Also See for E8F2:
Table of Contents

Advertisement

E8F2
Display Refresh Interval Setting
The following refresh intervals are selectable.
0.1: The average value is displayed at 0.1-s intervals.
0.5: The average value is displayed at 0.5-s intervals.
1.0: The average value is displayed at 1.0-s intervals.
OUT1 OUT2
kPa Torr Psi
or
1. Press the SET key while dsp is displayed to display the display refresh interval presently set.
2. Press the Up or Down key to change the set value.
3. Press the SET key to select the displayed set value and display dsp again.
4. Press the Up and Down keys simultaneously to display dsp again without selecting the set value.
Note: Set the AVE to the number of measurements for obtaining an average value.
Measurement Value Averaging Time Setting
The number of measurements can be set to 1, 8, 32, or 256.
OUT1 OUT2 kPa Torr Psi
or
1. Press the SET key while aUe is displayed to display the set value as the number of measurements for averaging measured values.
2. Press the Up or Down key to change the set value.
3. Press the SET key to select the displayed set value and display aUe again.
4. Press the Up and Down keys simultaneously to display aUe again without selecting the set value.
Note: If the DSP item is set to 0.5 and AVE item is set to 32, the E8F2 will measure 32 times, the average value of which will be treated
as one block. The average block value for 0.5 s will be displayed at 0.5-s intervals.
OUT1 OUT2
kPa Torr Psi
Press Up or Down key to
change set value.
OUT1 OUT2 kPa Torr Psi
Press Up or Down Key to
change set value.
18