Flushing Procedure

To avoid fire and explosion, always ground equipment
and waste container. To avoid static sparking and
injury from splashing fluid, always flush at the lowest
possible pressure.
Flush before changing colors, before fluid can dry in
the equipment, at the end of the day, before storing,
and before repairing equipment.
Flush at the lowest pressure possible. Check
connectors for leaks and tighten as necessary.
Flush with a fluid that is compatible with the fluid
being dispensed and the equipment wetted parts.
1. Follow the Pressure Relief Procedure, page 15.
2. Remove the retaining ring (8b), air cap (8a), and
spray tip (7).
3. Shut off the air supply.
Optional: Disconnect the air supply hose (H) from
the gun.
4. Change the fluid source to solvent or disconnect the
fluid line and connect a solvent supply line to the
gun.
3A8099A
Methylene chloride with formic or propionic acid will
damage aluminum and nylon components. Do not use
to flush or clean the gun.
5. Point the gun down into a grounded metal container.
Hold a metal part of the gun firmly to the grounded
metal container.
6. Increase the fluid pressure slowly.
7. Flush until clean solvent flows from the gun.
F
. 33: Flush gun into metal container
IG
8. Turn off the solvent supply.
9. Follow the Pressure Relief Procedure, page 15.