Maintenance

To reduce the risk of an injury, follow the Pressure
Relief Procedure, page 15, whenever you are
instructed to relieve the pressure.

Daily Gun Care

1. Follow the Pressure Relief Procedure, page 15.
F
. 25: Relieve the pressure
IG
2. Remove the air cap assembly (8) and spray tip (7).
7
8
F
. 26: Remove the air cap assembly and spray tip
IG
3. Flush the gun with a compatible solvent. Follow the
Flushing Procedure, page 21.
Methylene chloride with formic or propionic acid will
damage aluminum and nylon components. Do not use
to flush or clean the gun.
3A8099A
NOTICE
F
. 27: Flush the gun
IG
4. Soak the spray tip (7) in a compatible solvent.
F
. 28: Soak the spray tip
IG
5. Clean the air cap (8a), spray tip (7), and the outside
of the fluid cartridge (6) with a soft-bristle brush. See
Cleaning Procedure, page 22.
6
F
. 29: Clean parts with a soft-bristle brush
IG